Volume 32, Issue 12 pp. 3589-3598
Radiation imaging physics

The physics of computed radiography: Measurements of pulse height spectra of photostimulable phosphor screens using prompt luminescence

Kristina N. Watt, 

Kristina N. Watt

Sunnybrook and Women's College Health Sciences Centre, Department of Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada

Search for more papers by this author
Kuo Yan, 

Kuo Yan

Sunnybrook and Women's College Health Sciences Centre, Department of Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada

Search for more papers by this author
Giovanni DeCrescenzo, 

Giovanni DeCrescenzo

Sunnybrook and Women's College Health Sciences Centre, Department of Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada

Search for more papers by this author
J. A. Rowlands, 

J. A. Rowlands

Sunnybrook and Women's College Health Sciences Centre, Department of Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada

Electronic mail: [email protected]

Search for more papers by this author
First published: 15 November 2005

Abstract

Computed radiography (CR) is a digital technology that employs reusable photostimulable phosphor (PSP) imaging plates (IP) to acquire radiographic images. In CR, the x-ray attenuation pattern of the imaged object is temporarily stored as a latent charge image within the PSP. The latent image is optically readout as photostimulated luminescence (PSL) when the phosphor is subsequently stimulated using a scanning laser. The multiple stages necessary to create a CR image make it difficult to investigate either experimentally or theoretically. In order to examine the performance of the CR system at a fundamental level separate measurements of the processes involved are desirable. Here pulse height spectroscopy is used to study the prompt violet light emission or prompt luminescence (PL) from commercial PSP screens. Since the mechanism by which light escapes from the phosphor is identical for PL and PSL, observations and conclusions based on the pulse height spectra (PHS) of PL are relevant to the understanding of the behavior of the PSL light emission that outputs the radiographic image in CR. The PL PHS of screens of different thickness and optical properties were measured and compared with the PHS of conventional phosphors. A new method for calibration of the PHS in terms of the absolute number of optical photons per x-ray is introduced and compared to previously established methods.

Volume32, Issue12

December 2005

Pages 3589-3598